ForpostEngineered Site Protection

Materials and Standards

These are the starting points for the design. The final specification is set out in the working documentation for the site.

Request a Quote

Reading material parameters

Mesh opening, section size and coating thickness describe individual materials or components. They do not establish the performance of the whole structure. Selection considers the mesh, frame, connections, foundations and operating environment together.

What we clarify

  • Compare the specification with working drawings and site conditions.
  • Clarify delivery, installation and replacement requirements.
  • Do not treat a material property as system resistance without separate evidence.

Basis for the Design

These are the starting points for the design. The final specification is set out in the working documentation for the site.

Key Materials
StructureMaterialKey ParameterStandard
Masts and Screen FrameTube and sections per GOST 30245-20036–18 m spanSP 16.13330.2017
Mesh ScreenPolyester cord, steel mesh25–50 mm mesh openingGOST 5336-80
Gabion StructuresDouble-twist mesh, stone2 × 1 × 1 m moduleGOST R 52132-2003
Foundations and AnchoringB25 concrete, chemical and mechanical anchorsWind overturning momentSP 20.13330.2016
Personnel SheltersReinforced concrete rings, blocks and steel frameAt least 1.0 m of earth coverSP 88.13330.2022
Welded JointsSemi-automatic CO₂-shielded weldingWeld inspection, visual and dimensional checksGOST 14098-2014
Corrosion ProtectionPrimer-enamel, hot-dip galvanizing80–120 µm coating thicknessGOST 9.402-2004

Request a call

Leave your number and we can call you back.